Geogrids & Geocells

Steel-Plastic Geogrid

Product Description

A steel-core, polymer-coated reinforcement grid for high-load soil stabilization with low elongation.

Reference Standards / Selected Test Methods

ASTM D6637 / ISO 10319 / GB/T 17689

Applications: Soft-soil reinforcement · Roadbeds · Railway subgrades · Reinforced retaining walls · Slope stabilization

Specifications

MaterialSteel wire core with PE or PP coatingTypeUniaxial / biaxial / project aperture
Maximum tensile capacity150 kN/mElongation at break≤ 3%, typical series
Roll sizeCustom width × 50 m / 100 m

Performance varies between product series. Final specifications and acceptance criteria are subject to the technical documents agreed by both parties.

Technical performance

Parameters support product selection. Supply specifications and acceptance criteria follow the agreed technical documents. Batch inspection results are recorded in the corresponding test report.

JT/T 408-2008

↔ Swipe the table sideways, or use the scrollbar below.

Test itemUnitTGG 30-30TGG 40-40TGG 50-50TGG 60-60TGG 80-80TGG 100-100TGG 120-120TGG 150-150
Tensile yield force per unit width (MD)kN/m≥ 30≥ 40≥ 50≥ 60≥ 80≥ 100≥ 120≥ 150
Tensile yield force per unit width (CD)kN/m≥ 30≥ 40≥ 50≥ 60≥ 80≥ 100≥ 120≥ 150
Elongation at yield (MD / CD)%≤ 3≤ 3≤ 3≤ 3≤ 3≤ 3≤ 3≤ 3
Ultimate junction peel forceN≥ 100≥ 100≥ 100≥ 100≥ 100≥ 100≥ 100≥ 100

For the listed biaxial TGG models. Confirm directional strength, elongation and junction peel force for the selected model.

Ordering & delivery

Color
Black / custom
Warranty
Confirmed by project conditions and contract terms
Sample
Available; sample fee and freight confirmed by destination
Minimum order quantity
Confirmed by specification, roll size and packing plan

Supply conditions, payment and delivery arrangements are subject to the quotation or contract agreed by both parties.

Documentation

Factory quality inspection reports and material certificates can be provided after ordering. English certificates are available for overseas project submissions.

Product technical data sheet (TDS)

Confirmed according to the product series and specification

Request Technical Documents →
Factory quality inspection reports and material certificates

Available after ordering; specific documents are confirmed according to the order

Request Technical Documents →

Key Benefits

01

High tensile strength

Longitudinal and transverse strength of the selected TGG grade are checked separately against the factory table.

02

Low elongation

Elongation is confirmed for the grade; one property does not establish overall deformation control.

03

Corrosion resistance

Protective layer integrity and exposure conditions are confirmed for the project; avoid damage during installation.

04

High load capacity

Reinforcement performance requires verification of fill, layout, connections and compaction design.

Geogrids & Geocells

Why Choose Us?

01

Factory-Direct Production

Specifications are coordinated directly with our production team, making order progress, changes and batch records easier to track.

02

Project-Based Customization

Product dimensions and technical properties are confirmed according to project conditions and engineering requirements.

03

Complete Export Documentation

English test reports, shipping marks, packing lists and commercial invoices are available to support overseas project submissions.

04

Engineering Technical Support

Installation guidance is available to help confirm laying, joining and on-site inspection requirements.

Procurement FAQ · Geogrids & Geocells

Common Questions Before Ordering

Confirm the project conditions, applicable standard and required test documents before ordering. Our export and technical teams can assist with product selection, specification planning and delivery coordination.

Steel-Plastic Geogrid

01 Which tensile strength value should be used for geogrid selection?

Ultimate tensile strength alone is not sufficient. The design may require strength at a specified strain, junction efficiency, creep reduction, installation-damage and durability factors, leading to a long-term design strength. Confirm whether the specification calls for index strength or design strength before comparing quotations.

02 What is the correct installation sequence for reinforced road bases?

Prepare and compact the subgrade, place the reinforcement flat in the specified orientation, maintain overlaps or mechanical connections, anchor where required, then spread and compact fill without displacing the product. Equipment should not turn or brake directly on exposed reinforcement. The approved method statement governs the final sequence.

03 How are traffic loads and roadway class considered in product selection?

Provide axle load, traffic repetitions or design traffic, subgrade strength, aggregate properties, drainage, design life and pavement section. Temporary access roads, rural roads, highways, railways and working platforms require different verification. Our technical team can match available products to the design criteria but does not replace the project designer.

04 Can the factory customize dimensions and provide technical support?

Within production capability, roll or panel dimensions, strength grade, color, perforation, welding details, labels and export packaging can be reviewed for customization. We can provide product data, batch inspection, laying details and remote or agreed on-site guidance. Final structural design remains the responsibility of the project engineer.

Geogrids & Geocells

Recommended Products

Request a Quote for Steel-Plastic Geogrid

Provide the tensile specification, reinforcement direction, aperture size, quantity, application and destination port.