Landfill Liner Systems: Layer Sequence and Installation Details

The application of the pressure-sensitive solid-state earth/GCL, HDPE film, protective geotextile and silicon-based conduction layer, is accepted by the interface and transferred layer by layer.

The application of the pressure-sensitive solid-state earth/GCL, HDPE film, protective geotextile and silicon-based conduction layer, is accepted by the interface and transferred layer by layer.

Construction lessons

Project judgments and procurement conclusions

The filling site protective coating is not a single layer, but is made up of the ground, low-lying soil layer or GCL, HDPE main protective coating, protective layer and liquid-liquid conductive layer. Any upper layer that is not approved for coverage will permanently close the tipstone, water content abnormalities, connecting fault and drainage blind areas. Construction should use a clay separation transfer, concealed receipt, roll number and clay traceability CQA process.

Construction lessons

Steps to landing

  1. Dividing the construction unitsThe area of the welding and testing area is the area of the welding and testing area.
  2. The transfers are in writing.The first layer of the signature can be opened up to the next layer.
  3. Finished CQATesting, non-destructive testing, destruction of sampling and repair of the closed loop.
  4. Controlled paving and directing wasteLow-grade material, maintaining the required thickness protection.

Construction lessons

Key parameters and quick judgement tables

LevelsMain featuresCheck before transfer
Ground/pressure of solid soilStability and secondary barriersPressure intensity, water content, flatness
GCL (as designed)Low-grade coatingIt's a water-based, damaged connection.
HDPE geomembraneMain barrierThe number of volumes, the number of volumes, the defect graph
Protecting the layer of the fabric + conductorsAnti-puncture and excretionThe water is very dry, the pipes are sloping, the filling is clean.

Construction lessons

Acceptance points and common risks

  • GCL early hydrationRainfall or water accumulation can affect the quality of the padding and seam.
  • Pollution of the Protected LayerThe use of stone or building waste directly increases the risk of penetration.
  • The map of the location is perfectThe area has been repaired and the records have been reviewed.

Need a Geomembrane Quotation?

Prepare the thickness, quantity, application and destination port for an accurate quotation.